Technical data

Applied standards EN 60947-5-1, EN 60947-5-5, EN 60079-0, EN 60079-1, EN 60079-31, EN ISO 13849-1
Enclosure aluminium die-cast, enamel finish
Cover thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Degree of protection IP 65 to IEC/EN 60529
B10d (10 % load) 2 million
TM max. 20 years
Switch insert 1 x Ex 14
Contact material silver
Switching system slow action, positive break NC contacts 
Switching elements 1 NC/1 NO contact or 2 NC contacts, type Zb
Connection pre-wired cable H05VV-F
Cable cross-section 4 x 0.75 mm² (incl. conductor ferrules)
Cable length 3 m
Rated impulse withstand voltage Uimp 4 kV
Rated insulation voltage Ui 250 V
Conventional thermal current Ithe T6: 6 A, T5: 3 A
Rated operating current/voltage Ie/Ue 6 A/250 VAC; 0.25 A/230 VDC
Utilisation category AC-15; DC-13
Short-circuit protection 6 A gG/gN fuse
Ambient temperature T6: –20 °C … +65 °C,
T5: –20 °C … +75 °C, +90 °C with max. 3 A
Mechanical life > 1 million operations
Impact energy max. 7 J
Ex marking  II 2G Ex d IIC T6/T5 Gb,
 II 2D Ex tb IIIC
T80 °C/T95 °C Db
IECEx Ex d IIC T6/T5 Gb,
Ex tb IIIC T80 °C/T95 °C Db
Approvals PTB 11 ATEX 1003 X
IECEx PTB 07.0034 X
   

Recent articles

The Future of Trucking: Navigating Innovation and Sustainability

Article - 1 month ago

The trucking industry has long been the backbone of global commerce, responsible for transporting approximately 70% of freight in the United States al...

Read more...

What are the collaborative robots ( cobots)

Article - 4 years ago

Here, at Automation Center, we collaborate and we install machines as ABB, KUKA, FANUC, YASKAWA, UNIVERSAL ROBOT or Mitsubishi. We also create robotic...

Read more...

Heavy-Duty and ATEX encoders: rugged to deal with the roughest conditions

Article - 3 years ago

Harsh and hazardous environments require tough encoders with reliable and solid design, rugged mechanics, high reliability components, immunity to i...

Read more...

Tags